2 introduction, Caution, Overview – Omni Group GREEN SMART 864 User Manual

Page 2: Listing details, Ias (icbo) approval, Massachusetts approval, National fireplace institute, Ias # tl130

Advertising
background image

2 Introduction

© Travis Industries

4090507

100-01217_000

Overview

This manual details the installation requirements

for the 864 See Through (ST) GS fireplace. For

operating and maintenance instructions, refer to

the 864 ST GS Owner's Manual (part # 100-

01218).

Listing Details

This appliance was listed to ANSI Z21.88. The

listing label is attached to the appliance near the

gas control valve. A copy is shown to the right.

IAS (ICBO) Approval

IAS # TL130.

Massachusetts Approval

This manual has been submitted to the

Massachusetts Board of State Examiners of

Plumbers and Gas Fitters.

National Fireplace Institute

Report No. 028-F-84-5

Certified for USA

and Canada

Portland

Oregon USA

Tested &

Listed By

V

ented Gas Fireplace Heater

864 ST GS

Tested to:

ANSI Z21.88a-2007/CSA

2.33a-2007 “V

ented Gas Fireplace Heater”, CGA

2.17-M91 “Gas Burning

Heating

Appliances for Manufactured Homes”, and CSA

P

.4.1-02 T

esting method for measuring annual fireplace

efficiency

.

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas

Code,

ANSI Z223.1/NFP

A

54, or Natural Gas and Propane Installation Codes, CSA

B149.1.

This appliance must be installed in accordance with the current Standard CAN/CSA

Z240 MH, Mobile Housing,

in Canada or with the Manufactured Home Constructions and Safety Standard, T

itle 24 CFR, Part 3280, in the

United States, or when such a standard is not applicable,

ANSI/NCSBCS

A225.1/NFP

A

501A, Manufactured Home

Installation Standard.

This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP)

is desired, the optional factory conversion kit must be used. Part No. 250-02383 register kit may be used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an

aftermarket, permanently located, manufactured home (USA

only) or mobile home, where not prohibited by local

codes. See owner

’s manual for details. This appliance is not convertible for use with other gases, unless a

certified kit is used.

This vented gas fireplace heater is not for use with air filters.

Keep burner and control compartment clean. See installation and operating instructions accompanying

appliance.

This appliance must be properly connected to a venting system in accordance with the manufacturer

’s

installation instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior

. See

owner

’s manual for approved brands of venting.

If the vent-air intake system is disconnected for servicing or any other reason, it must be resealed and / or

reinstalled.

W

ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property

damage. Refer to the owner

’s information manual provided with this appliance. For assistance or additional

information consult a qualified installer

, service agency or the gas supplier

.

VENTED GAS FIREPLACE HEA

TER - NOT FOR USE WITH SOLID FUEL

Minimum Clearances to Combustibles

Fireplace to

Adjacent W

all

W

ood Floor Beneath Fireplace

Back to Enclosure

1” (26mm)

0” (0mm)

42” (1067mm)

Header (from Stand-Offs)

Sides to Enclosure

Base of Fireplace to a Mantel

0” (0mm)

Left Side: 0.5” (13mm)

Right Side: 0” (0mm)

See Owner

’s Manual

FAN TYPE VENTED CIRCULA

T

OR

Blower Electrical Rating: 1

15V
., 1.5

Amps, 60 Hz Part No. 99000164 fan or blower assembly may be used.

DANGER! Risk of Electric Shock. Disconnect power before servicing unit.

Minimum Inlet Pressure (inches W

.C.)

Maximum Inlet Pressure (inches W

.C.)

Manifold Pressure on “HI” (inches W

.C.)

L.P
.

11

13”

10”

N.G.

5.5”

7”

3.5”

Input Rate on “HI” (BTU/Hr)

Input Rate on “LO” (BTU/Hr)

Orifice Size - Outer (DMS)

Orifice Size - Center (DMS)

L.P
.

37,500

10,000

#55

#55

N.G.

37,500

14,700

#44

#48

This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).

For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.

See owner

’s manual for information on making these changes.

2014

2015

2013

Feb.

Mar

.

Jan.

May

Jun.

Apr

.

Aug.

Sep.

Jul.

Nov

.

Dec.

Oct.

MANUF

ACTURE DA

TE:

W

ARNING: Failure to install this appliance per the manufacturer

’s instructions or failure to use only parts

specifically approved with this appliance may result in property damage or personal injury

.

4800 Harbour Pointe Blvd. SW

Mukilteo, W

A

98275

Manufactured by:

www

.travisproducts.com

CAUTION:

Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done

by a licensed or qualified service person.

0639

Advertising