Quadra-Fire QFP38-NG User Manual

Page 15

Advertising
background image

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

15

Temperature Indication Display

With the system in the OFF position, press the THERMOSTAT key and the MODE key at the same time. Look at the LCD
screen on the transmitter to verify that a C or F is visible to the right of the room temperature display. (Figure 2.9.)

Turn on the Appliance

Press the ON/OFF key on the transmitter. The transmitter display will show all active icons on the screen. At the same
time the receiver connects, the thermopile to the gas valve millivolt coil and the appliance main burner turns on. A single
“beep” from the receiver will confi rm reception of the command.

Turn off the Appliance

Press the ON/OFF key on the transmitter. The transmitter LCD display will only show the room temperature and icon. At
the same time the receiver disconnects, the thermopile from the gas valve millivolt coil and the appliance burner turns off.
A single “beep” from the receiver confi rms reception of the command.

Figure 2.9 Remote Control Display in Farenheit & Celsius

Figure 2.10 Remote Control Display

Advertising
This manual is related to the following products: