I. install horizontal termination cap – Quadra-Fire QFP38-NG User Manual

Page 47

Advertising
background image

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

47

INTERIOR

Heat Shield or

Extended

Heat Shield

Wall Shield

Firestop

Heat Shield

1-1/2 in. (38 mm) min.

overlap

SHEATHING

Slip Section

can be extended

Inner Vent

Outer Vent

EXTERIOR

Figure 10.16 Venting through the wall

Note: When using termination caps with factory-supplied
heat shield attached, no additional wall shield fi restop is
required on the exterior side of a combustible wall.

I. Install Horizontal Termination Cap

WARNING! Risk of Fire!

The telescoping fl ue section

of the termination cap MUST be used when connecting
vent.

• 1-1/2 (38 mm) minimum overlap of fl ue telescoping

section is required.

Failure to maintain overlap may cause overheating and
fi re.

•

Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.

• Flash and seal as appropriate for siding material at

outside edges of cap.

• When installing a horizontal termination cap, follow

the cap location guidelines as prescribed by current
ANSI Z223.1 and CAN/CGA-B149 installation codes
and refer to Section 6 of this manual.

CAUTION! Risk of Burns!

Local codes may require

installation of a cap shield to prevent anything or anyone
from touching the hot cap.

NOTICE:

For certain exposures which require superior

resistance to wind-driven rain penetration, a fl ashing kit and
HPC caps are available. When penetrating a brick wall, a
brick extension kit is available for framing the brick.