53

BLACK

WHITE

GROUND

14-2 with

Ground Romex

Figure 13.4 Junction Box Detail

14-2 with ground Romex is the recommended wiring
to the appliance junction box.

D. Junction Box Installation

• Remove junction box from outer shell.
• Remove front cover from junction box.
• Knock out hole in junction box back and install Romex

connector.

• Feed necessary length of wire through connector.
• Make all wire connections to receptacle as shown in

Figure 13.4.

• Reassemble jumction box with receptacle inside.
• Insert junction box and receptable assembly through

hole in outer shell (see Figure 13.3) and fasten with two
screws.

Figure 13.3 Remove Junction Box Assembly

E. Heat-Zone-Gas

Install the Heat Zone Kit before enclosing the appliance.

Remove one of two square cover plates for each kit from
the top of the appliance. Set the screws aside, discard
the cover plate.

• Replace the cover plate with the heat zone collar from

the kit. Use the three screws removed from the cover
plate.

• Return to Heat-Zone-Gas instructions.

Cover Plates

Figure 13.5 Cover Plates