Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

53

BLACK

WHITE

GROUND

14-2 with

Ground Romex

Figure 13.4 Junction Box Detail

14-2 with ground Romex is the recommended wiring
to the appliance junction box.

D. Junction Box Installation

• Remove junction box from outer shell.
• Remove front cover from junction box.
• Knock out hole in junction box back and install Romex

connector.

• Feed necessary length of wire through connector.
• Make all wire connections to receptacle as shown in

Figure 13.4.

• Reassemble jumction box with receptacle inside.
• Insert junction box and receptable assembly through

hole in outer shell (see Figure 13.3) and fasten with two
screws.

Figure 13.3 Remove Junction Box Assembly

E. Heat-Zone-Gas

Install the Heat Zone Kit before enclosing the appliance.

•

Remove one of two square cover plates for each kit from
the top of the appliance. Set the screws aside, discard
the cover plate.

• Replace the cover plate with the heat zone collar from

the kit. Use the three screws removed from the cover
plate.

• Return to Heat-Zone-Gas instructions.