To replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows can be replaced with two 45°
elbows.

General Rules:

• SUBTRACT 3 ft. from the total H measurement for each 90° elbow installed horizontally.
• SUBTRACT 1-1/2 ft. from the total H measurement for each 45° elbow installed horizontally.

A maximum of three 90° elbows (or six 45° elbows) may be used in any vent confi guration. Some elbows may be installed
horizontally. See Figure 7.5.

• Elbows may be placed back to back anywhere in the system as long as the fi rst 90° elbow is a starter elbow except as

shown in Figure 7.4.

• When penetrating a combustible wall, a wall shield fi restop must be installed.
• When penetrating a combustible ceiling, a ceiling fi restop must be installed.
• Horizontal runs of vent do not require vertical rise; horizontal runs may be level.

E. Vent Diagrams

Figure 7.3

One Elbow

1. Top Vent - Horizontal Termination

V

1

Min.

V

1

Max.

H

1

Max.

feet

1

-

5

meters

0.30

1.52

feet

2

-

10

meters

0.61

3.05

feet

3

-

15

meters

0.91

4.57

feet

4

-

20

meters

1.22

6.10

feet

25

20

meters

7.62

6.10