I. adjust the air shutter, J. adjust the vertical baffl e – Quadra-Fire QFP38-NG User Manual

Page 62

Advertising
background image

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

62

• Repeat with the other light box.

Figure 15.26 Finished Assembly

Switch the control module to “ON” and/or plug light cord
(white) into module.

Plug brown wires into the back of the ON/OFF switch on
the dashboard, reattach dashboard with the two screws
removed in the fi rst step.

To Close
To Open

Air Shutter

Adjustment

Remove
Screw

Replace

Screw

Rotate

Lever

1

2

3

4

Position 1 - Horizontal and up to 8 ft (2.45 m) vertical
Position 2 - 8-16 ft (2.45-4.88 m) vertical
Position 3 - 16-30 ft (4.88-9.14 m) vertical
Position 4 - Over 30 ft (9.14 m) vertical

Figure 15.28 Adjust the Vertical Baffl e

Figure 15.27 Adjusting the Air Shutter

I. Adjust the Air Shutter

This appliance has two adjustable air shutters (to control
the primary air) which are set at the factory.

• A natural gas unit is set in the closed position.
• An LP gas unit is set in the open position. See

Figure 15.27.

If it is necessary to adjust the air shutter to obtain
optimal fl ame appearance, this should be adjusted by
a qualifi ed installer.

J. Adjust the Vertical Baffl e

If the vertical vent run height is more than 8 ft (2.45 m),
it may be necessary to adjust the vertical baffl e installed
in the unit to improve the fl ame appearance. See Fig-
ure 15.28.