B. Vent Components Diagrams (continued)

Figure 17.5 DVP Vent Components

DVP-HPC1

DVP-HPC2

DVP-TRAPK1

DVP-TRAPK2

DVP-TRAP

Horizontal Termination Cap

15-1/8 in.

(384 mm)

12 in.

(305 mm)

8 in.

(203 mm)

Max

Effective

Length

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick.
If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.

Heat

Shield

Term Cap

Minimum

Effective Length

Maximum

Effective Length

Trap1

3-1/8 in.

4-5/8 in.

79 mm

117 mm

Trap2

5-3/8 in.

9-3/8 in.

137 mm

238 mm

Fillers

DVP-TRAP to DVP-HPC Side Filler Kit