D. mantel and wall projections, Mantels mantel legs or wall projections – Quadra-Fire QFP38-NG User Manual

Page 30

Advertising
background image

Quadra-Fire • QFP38 Series • 4061-300 Rev i • 9/09

30

Measured from appliance opening (in inches)

0 - 10

11

12

22

22 1/2

23

30 in. minimum

to ceiling

D. Mantel and Wall Projections

WARNING! Risk of Fire!

Comply with all minimum clear-

ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).

Figure 5.3

Clearances to Mantels or Other Combustibles above

Appliance

5 in. (127 mm) Min.
to perpendicular wall

A

6 in. (152 mm) Min.
from fireplace opening
to perpendicular wall

B

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

B

Figure 5.4

Mantel Leg or Wall Projections (Acceptable on both

sides of opening)

Mantels

Mantel Legs or Wall Projections