Page 13: B. use of elbows, A. vent table key, C. measuring standards

Advertising
background image

13

Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11

Fire Hazard.

Explosion Risk.

Asphyxiation Risk.

Do NOT connect this gas appliance to a chimney
fl ue serving a separate solid-fuel or gas burning
appliance.

• Vent this appliance directly outside.

• Use separate vent system for this appliance.

May impair safe operation of this appliance or
other appliances connected to the fl ue.

CAUTION

ALL vent confi guration specifi cations MUST be followed.

• This product is tested and listed to these specifi cations.

• Appliance performance will suffer if specifi cations are not

followed.

B. Use of Elbows

Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect (see
Figure 5.1).

Two 45º elbows may be used in place of one 90º elbow. On
45º runs, one foot of diagonal is equal to 8-1/2 (216 mm)
inches horizontal run and 8-1/2 (216 mm) inches vertical
run. A length of straight pipe is allowed between two 45º
elbows (see Figure 5.1).

Figure 5.1

5

5

Vent Information and Diagrams

A. Vent Table Key

The abbreviations listed in this vent table key are used in
the vent diagrams.

C. Measuring Standards

Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.

1. Pipe measurements are shown using the effective length

of pipe (see Figure 5.2).

2. Measurements are made from the appliance outer wrap,

not from the standoffs.

3. Horizontal terminations are measured to the outside

mounting surface (fl ange of termination cap) (see
Figure 4.1).

4. Vertical terminations are measured to bottom of termi-

nation cap.

5. Horizontal pipe installed level with no rise.

Figure 5.2 DVP Pipe Effective Length

Effective

Height/Length

Symbol

Description

V

1

First section (closest to appliance) of vertical length

V

2

Second section of vertical length

H

1

First section (closest to appliance) of horizontal length

H

2

Second section of horizontal length

Horizontal

Vertical

8-1/2 in.

8-1/2 in.

12 in.

Pipe

Effective Length

Inches

Millimeters

DVP4

4

102

DVP6

6

152

DVP12

12

305

DVP24

24

610

DVP36

36

914

DVP48

48

1219

DVP6A

3 to 6

76 to 152

DVP12A

3 to 12

76 to 305

DVP12MI 3 to 12

76 to 305

DVP24MI 3 to 24

76 to 610

WARNING