Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11

32

CAUTION

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.

Shock hazard.

• Replace damaged wire with type 105º C rated

wire.

• Wire must have high temperature insulation.

Figure 10.2 Light enclosure

WARNING

Wiring for optional accessories should be done now to
avoid reconstruction.

LIGHT BULBS

This appliance has standard fi rebox lighting. The 20 watt
halogen bulbs are not factory installed. The lights are ac-
cessible from under the fi rebox in the valve area.

To Replace a Light Bulb:

The lights are shipped in boxes in the light enclosures.
Reach behind the valve and locate the light boxes. Cut
the rubber band and slide out the back of the light box.
Remove the light bulb from the box and install it in the
socket. Replace the back of the enclosure.

Introduction

The QWSK-MLT multifunctional wall switch is designed
to control fl ame height, blower speed, and auxiliary
functions on your gas fi replace. For models equipped with
the Intellifi re system (IPI), the cold climate function can
control the pilot fl ame as well. The wall switch is equipped
with thermostat functions which can automatically control
the temperature in the room in which it is installed. The
wall switch interfaces with both intermittent and standing
pilot systems. An auxiliary function provides 110-120
VAC source for added features the fi replace may have
installed. Electrical ratings for the control box are 110
VAC, 60 Hz, and is required for operation of this device.

Installation precautions

This remote is tested and safe when installed in accordance
with this installation manual. It is your responsibility to
read all instructions before starting installation and to
follow these instructions carefully during installation. Do
not install any components that may be damaged. Do not
modify, disassemble, or substitute any of the components
included with this kit. Installation of this unit must be done
by a qualifi ed service technician.

Placement of this wall switch may affect performance
or accuracy of the automatic (thermostat) control. An
assessment of the space should be done prior to
installation for optimal performance. See the installation
instructions section I for recommendations.

NOTE: The electrical junction box provided with the
fi replace must be wired with 110 VAC.

All wiring should be done by a qualifi ed electrician and
shall be in compliance with local codes and with the
National Electric Code ANSI/NFGA No. 70- current (in the
United States), or with the current CSA C22.1 CANADIAN
ELECTRIC CODE (in Canada).

WARNING

Shock Hazard

Do not provide any power to this unit until all
wiring is completed. Failure to do so may destroy
parts of this device and render it unusable, and
may lead to possible electrical shock.

Fire Hazard

Modifi cation of any parts or installation of
damaged components will void the warranty,
and you may possibly cause a fi re hazard.