Warning, D. installing non-combustible facing material – Quadra-Fire Expression 36 QV36A-FB User Manual

Page 22

Advertising
background image

Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11

22

Fire Risk.

• Follow these instructions exactly.

• Facing materials must be installed properly to

prevent fi re.

• No materials may be substituted without

authorization by Hearth & Home Technologies.

WARNING

APPLY FASTENERS FROM

FASTENER PACKET IN

THESE AREAS

NON-COMBUSTIBLE

FACING MATERIAL

(SUPPLIED ATTACHED

TO BACK OF APPLIANCE).

STEEL BACK SUPPORT

(SUPPLIED ATTACHED TO

TOP OF APPLIANCE).

Figure 7.9 Attaching Non-combustible Facing Material

D. Installing Non-combustible Facing Material

• Center and attach two top boards to the framing

members. See Figure 7.10.

• Use fasteners from fastener packet (in manual bag) in

shaded areas.

• Use regular sheetrock screws in non-shaded areas.

• Use a wet or dry towel or soft brush to remove dust or

dirt from facing material.

• Apply a non-combustible adhesive to attach tile,

stone or other non-combustible fi nishing materials per
manufacturer’s instructions.

Figure 7.10 Complete Installation of Non-combustible
Facing

Material

44 in.

1117 mm

18-1/4 in.

463 mm

34-5/8 in.

879 mm

Non-combustible

Zone

Advertising