F. junction box installation – Quadra-Fire Expression 36 QV36A-FB User Manual

Page 35

Advertising
background image

35

Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11

WHT

WHT

BLK

BLK

GRN wire
inside box

Copper
ground attached
to GRN screw with
GRN wire

14/2WG

Cover Plate
outside firebox

Romex
Connector

F. Junction Box Installation

If the box is being wired from the OUTSIDE of the appli-
ance:

• Remove the cover plate located on the outer shell - right

side (see Figure 10.6).

• Install the supplied Romex™ connector in the cover plate.

• Feed the necessary length of wire through the connector.

• Make all necessary wire connections and reattach the

cover plate to the outer shell.

If the box is being wired from the INSIDE of the appliance:

• Remove the screw attaching the junction box/receptacle

to the outer shell, rotate the junction box inward to
disengage it from the outer shell (see Figure 10.6).

• Pull the electrical wires from outside the appliance

through this opening into the valve compartment.

• Feed the necessary length of wire through the connector.

• Make all necessary wire connections to the junction box/

receptacle and reassemble the junction box/receptacle
to the outer shell.

Figure 10.6 Junction Box Detail

Note: Do NOT wire
110VAC to wall switch.

Figure 10.5.

BATTERY

OPERATION

SWITCH

“BATTERY ON”

POSITION

POSITION

CONTROL

BOX