Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11

A. Recommendation for Wire

This appliance requires 110-120 VAC be wired to the
junction box either for use of optional accessories or for
proper operation of the appliance.

10

10

Electrical Information

Note: This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local
codes, with National Electric Code ANSI/NFPA 70-latest
edition
or the Canadian Electric Code, CSA C221.1.

B. Connecting to the Appliance

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

• Incorrect wiring will damage millivolt valves.

• Uninterrupted or continuous power is required

at all times in IPI system EXCEPT when using
battery back-up.

C. IntelliFire Ignition System Wiring

This appliance requires a 110 VAC supply to the appli-
ance junction box for operation. A wiring diagram is shown
in Figure 10.1.

This appliance is equipped with an IntelliFire control valve
which operates on a 3 volt system.

This appliance is supplied with a battery pack and a 3 volt
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junc-
tion box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not includ-
ed). Batteries cannot be placed in the battery pack while
using the 3 volt AC transformer. Conversely, the trans-
former must be unplugged if the battery pack is used.

CAUTION

Battery polarity must be correct or module damage will
occur.

WARNING

Figure 10.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram

Note 1: Ignition module, valve, pilot
and wall switch operate on 3 volts.

Note 2: Plug QWSK-MLT wall switch
kit into the REM/AUX outlet on the
junction box.

IPI

VALVE

ORANGE

WIRES WITH LABEL “FOR USE WITH REMOTE OR WALL SWITCH ONLY”

(LOCATED UNDER FIREPLACE)

GREEN

RED

RED

GROUND

PIGTAIL

GREEN

AUX

CONNECTION

FRONT VIEW

REAR VIEW

G Y R

BLACK

BLACK

AC

PLUG

FAN

CONNECTION

ORANGE

BATTERIES

1
2
3
4
5
6
7
8

R

Y

G

ORANGE

IPI

MODULE

FLAME

SOLENOID

FLAME HIGH/LOW

BLACK

RED

BLACK

RED

RED

BLACK

RED

(MALE/FEMALE)

RED

(FEMALE/MALE)

ADAPTER WIRES

BROWN

BROWN

GROUND

BLACK

BROWN

BROWN

RED

GREEN

YELLOW (HNG)

WHITE (HTL)

BATTERY

IPI PILOT

3V DC

FLAME ON

YELLOW

YELLOW

FAN THERMOSTAT

FACTORY

CONNECTED

TOGETHER

CONTINUOUS

110VAC

SUPPLY

BLACK

WHITE

GROUND

HOT

FA

N

TRANS

REM/AUX

NEUTRAL

FIREBOX LIGHTS

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when it is
installed in locations such as in bathrooms or near sinks.

• Incorrect wiring will override IPI safety lockout and may

cause explosion.