EMAC Module Registers

Table 66. MAC Control Register (MACCONTROL) Field Descriptions (continued)

Bit

Field

Value

Description

4

TXFLOWEN

Transmit flow control enable bit. This bit determines if incoming pause frames are acted upon
in full-duplex mode. Incoming pause frames are not acted upon in half-duplex mode,
regardless of this bit setting. The RXMBPENABLE bits determine whether or not received
pause frames are transferred to memory.

0

Transmit flow control is disabled. Full-duplex mode: incoming pause frames are not acted
upon.

1

Transmit flow control is enabled. Full-duplex mode: incoming pause frames are acted upon.

3

RXBUFFERFLOWEN

Receive buffer flow control enable bit

0

Receive flow control is disabled. Half-duplex mode: no flow control generated collisions are
sent. Full-duplex mode: no outgoing pause frames are sent.

1

Receive flow control is enabled. Half-duplex mode: collisions are initiated when receive buffer
flow control is triggered. Full-duplex mode: outgoing pause frames are sent when receive flow
control is triggered.

2

Reserved

0

Reserved

1

LOOPBACK

Loopback mode. The loopback mode forces internal full-duplex mode regardless of the
FULLDUPLEX bit. The loopback bit should be changed only when GMIIEN bit is deasserted.

0

Loopback mode is disabled.

1

Loopback mode is enabled.

0

FULLDUPLEX

Full duplex mode.

0

Half-duplex mode is enabled.

1

Full-duplex mode is enabled.