4 receive revision id register (rxrevid), 5 receive control register (rxcontrol), Section 5.4 – Texas Instruments TMS320C674X User Manual

Page 88: Section 5.5

Advertising
background image

EMAC Module Registers

www.ti.com

5.4

Receive Revision ID Register (RXREVID)

The receive revision ID register (RXREVID) is shown in

Figure 42

and described in

Table 41

.

Figure 42. Receive Revision ID Register (RXREVID)

31

0

RXREV

R-4EC0 020Dh

LEGEND: R = Read only; -n = value after reset

Table 41. Receive Revision ID Register (RXREVID) Field Descriptions

Bit

Field

Value

Description

31-0

RXREV

Receive module revision

4EC0 020Dh

Current receive revision value

5.5

Receive Control Register (RXCONTROL)

The receive control register (RXCONTROL) is shown in

Figure 43

and described in

Table 42

.

Figure 43. Receive Control Register (RXCONTROL)

31

16

Reserved

R-0

15

1

0

Reserved

RXEN

R-0

R/W-0

LEGEND: R/W = Read/Write; R = Read only; -n = value after reset

Table 42. Receive Control Register (RXCONTROL) Field Descriptions

Bit

Field

Value

Description

31-1

Reserved

0

Reserved

0

RXEN

Receive enable

0

Receive is disabled.

1

Receive is enabled.

88

EMAC/MDIO Module

SPRUFL5B – April 2011

Submit Documentation Feedback

© 2011, Texas Instruments Incorporated