Restore Data

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

104

DKAdmin/DKBackup

Important!

These messages display

6. Press

Enter

and the following screen displays:

Processor Conversion

PLEASE READ THE FOLLOWING SCREENS AS THEY PROVIDE VERY IMPORTANT
INFORMATION REGARDING THE UPGRADE AND INITIALIZATION PROCESSES.

Please turn DK system power off and add/change cabinets, processor ROM or
RMSS memory and/or RCTU PCBs as required.

IMPORTANT: Do not add PCBs, other than RSIU or PIOU in between existing
PCBs at this time as they will make station port and/or CO line numbers
shift causing the upgraded data to be invalid.

The next screen provides step-by-step instructions for initializing the
system.

Press any key to Continue

Processor Conversion

Step A: After changing the processor, you should initialize the new

processor by running Program 91-9 manually from the Programming
Telephone. Then you must reset the PIOU, PIOUS, RSSU, or RSIU/
RSIS/RMDS TTY port that is connected to DKAdmin PC by performing
Step B and/or C.

Step B: From the Programming Telephone, use Program 03 to set code 41 for

the cabinet slot that contains the new TTY/Maintenance PIOU,
PIOUS, or RSSU PCB and proceed to Step D. If you added an RSIU/
RSIS/RMDS PCB, set code 49 for cabinet slot 11 and proceed to Step
C.

Step C: From the Programming Telephone, use Program 76-1 and 76-2 to set

the RSIU/RSIS/RMDS ports for their appropriate functions and baud
rates. DKAdmin will pull Program 76 and adjust the DKAdmin
customer database accordingly. Make sure the TTY/Maintenance port
settings are correct to insure a successful Upgrade process.
Proceed to Step D.

Step D: Turn DK off (5 sec) then on. From the Programming Telephone, test

the RCTU (R3) RAM by running Program 00-(51,52/61, 62)

Press any key to Continue