Toshiba Strata DK Backup User Manual

Page 168

Advertising
background image

DK424 Release 4.0 Upgrade Programming Example

–––––––––––––––––––––––––––––––––––––––––––––––––––

158

DKAdmin/DKBackup

Programs *04, 05, 09

There is no change to the data in these programs when upgrading to Release 4.0. Note that
DID/Tie ports do not cause Phantom DN ports to shift in Strata DK Release 1~Release 3
systems, so they do not shift in Program

*

04 when upgrading to Release 4.0. Also, the data in

Program 09 is DN numbers and not port numbers, so data in Program 09 does not change
when upgrading to Release 4.0.

Program *09

Data in this program must be changed to adjust for port shifting caused by the RDDU DID line
PCB in slot 13 (see

Figures 33

and

34

):

Programs 10-1 through 10-4

There is no change to the data in these system programs when upgrading to Release 4.0. Port
numbers are not assigned to system programs so no adjustments are necessary.

Program 13

If the Message Center is the Front Office Telephone (PDN 112), data in this program must be
changed to adjust for port shifting caused by the RDDU DID line PCB in slot 13 (see

Figures

33

and

34

):

Data for Program 13 before the upgrade = 012

Data for Program 13 after the upgrade = 008

If the Message Center is the Lobby Telephone (PDN 100), data in this program must not be
changed to adjust for port shifting caused by the RDDU DID line PCB in slot 13. This is
because Port 000 did not shift after the upgrade (see

Figures 33

and

34

):

Data for Program 13 before the upgrade = 000

Data for Program 13 after the upgrade = 000

Programs 15, 16, and 17

There is no change to the data in these programs when upgrading to Release 4.0. These are CO
line programs and port numbers are not assigned in them so no adjustments are necessary.

Program *17

If the DID Intercept Destination is the Back Room Telephone (PDN 119), data in this program
must be changed to adjust for port shifting caused by the RDDU DID line PCB in slot 13 (see

Figures 33

and

34

):

Program

*

17 data for DID lines 001~004 before the upgrade = 019

Program

*

17 data for DID lines 001~004 after the upgrade = 015

Before the Upgrade

After the Upgrade

Port 000-007; Data 100-107

Port 000-007; Data 100-107

Port 008-015; Data 108-115

Port 008-015; Data 112-119

Port 016-019; Data 116-119

Port 016-019; Data Blank

Advertising
This manual is related to the following products: