DK424 Release 4.0 Upgrade Programming Example

–––––––––––––––––––––––––––––––––––––––––––––––––––

154

DKAdmin/DKBackup

DK424 Release 4.0 Upgrade Programming Example

Important!

When upgrading to DK424 Release 4.0 from a lower release, it is highly
recommended to use the DKAdmin or DKBackup Release 4.0 PC software
program. Trying to upgrade to Release 4.0 manually from the programming
telephone could take many hours.

The following Release 3.0 to Release 4.0 upgrade example demonstrates some basic
programming changes automatically performed by DKAdmin due to station port shifting.
Station port shifting only occurs when station PCBs are in higher numbered slots than Tie and/
or DID lines.

This example does not give you every program change required, nor does it attempt to instruct
you on how to re-program a system upgraded to Release 4.0, using the programming
telephone. This is a simple system upgrade; an actual installed systems can be much more
complex to upgrade.

Cabinet Station Port Counting Before/After Release 4.0 Upgrade

Figures 31

shows the DKAdmin cabinet drawing of a DK424 system with an:

RCTUE3/F3 processor

RSIU interface

16 Digital telephones

4 analog DID lines

Notice that the RDDU PCB increments the station ports by four ports.

Figure 31

Cabinet Drawing for RCTUE3/F3 Before Release 4 Upgrade

Figure 32

shows the same DKAdmin cabinet drawing after upgrading to an RCTUE3/F4 with

DKAdmin.

Notice that the telephones connected to the PDKU2 in slot 14 were on ports 012~019 but are
now on ports 008~015, respectively. This phenomenon requires many programming changes
to enable the DK system to operate the same as it did prior to the upgrade. DKAdmin/
DK Backup Release 4.0 is designed to make all programming changes automatically to enable
the upgrade to be transparent to the system operation.

Figure 32

Cabinet Drawing for RCTUE3/F4 After Release 4 Upgrade

PCB Placement per Program 03

Cabinet 1

R11

RCTU

S11

S12

S13

S14

S15

S16

PCB Type

RCTUE3

RCTUF3

RSIU

PDKU2

RDDU

PDKU2

Port Nos.

000~007

008~011

012~019

Line Nos.

001~004

Option/Note

PCB Placement per Program 03

Cabinet 1

R11

RCTU

S11

S12

S13

S14

S15

S16

PCB Type

RCTUE3

RCTUF4

RSIU

PDKU2

RDDU

PDKU2

Port Nos.

000~007

008~015

Line Nos.

001~004

Option/Note

Advertising