On-site upgrade – Toshiba Strata DK Backup User Manual

Page 156

Advertising
background image

Upgrading to RCTUE/F

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

146

DKAdmin/DKBackup

5. Using the Backup/Restore Data function on the Administration Menu, download the

complete customer database via modem or disk by pressing

F2

then

F3

.

After the customer database is downloaded and built, it can be upgraded to the RCTUE/F
processor.

6. Install the RCTUE/F processor into the DK280 or DK424 base cabinet (see the Strata

I&M Manual for more details). Remove the MBJU (DK424 Base only).

7. From the programming telephone, run Program 91-9 twice to initialize the RCTUE/F

processor.

8. From the programming telephone run Programs 03, 76, and 77-1 to set up the TTY

interface port.

9. Turn the system power off for five seconds then turn the power back on.

10. Connect the DKAdmin PC to the system TTY interface port; check communication

between the DKAdmin program and RCTUE/F processor is operating properly.

11. Using DKAdmin, select the customer database created in

Step 2

.

12. Check the PCB code for the TTY PCB (PIOU, RSIU, etc.) is set properly in Program 03.

13. From the Administration Menu, select the Back/Restore Data function and press

Enter.

Press

F5

to select Upgrade.

14. Follow the upgrade steps in DKAdmin; select the RCTUE/F processor. Answer

No

to

“Backup From DK First?” and

No

to “Pull Program 03?”.

15. After DKAdmin upgrades and uploads the customer database, it prompts you to “Perform

Automatic Power OFF/ON”; answer

Yes

. DKAdmin runs Program 91-2, then prompts

you to receive data to complete the upgrade process; answer

Yes

. DKAdmin downloads

the upgraded RCTUE/F database and builds the customer file.

16. The upgrade is now complete. Install the upgraded RCTUE/F at your customer site.

On-Site Upgrade

If upgrading on-site, the DKAdmin upgrade process pulls the current existing customer
database.

To do an on-site upgrade

1. Connect the DKAdmin PC to the system TTY interface port; check that DKAdmin is

communicating with the existing RCTU processor.

2. From the File Menu, type

m

to select the Maintain Customer File function.

3. Create a new customer database by selecting the existing DK16e or RCTU (A, B, BA/BB,

or C/D) and Release (Release 1/Release 2 or Release 3 version).

4. Select the new customer created in

Step 3

5. From the Administration Menu, select the Back/Restore Data function and press

Enter.

Press

F5

to select Upgrade.

6. Follow the upgrade steps in DKAdmin; select the RCTUE/F processor. Answer

Yes

to

“Backup From DK First?” and

Yes

to “Pull Program 03?”. DKAdmin downloads the

database from the existing RCTU processor.

7. After DKAdmin downloads the database from the existing RCTU processor, DKAdmin

prompts you to change the processors etc. (i.e., turn power off, remove the existing