Toshiba Strata DK Backup User Manual

Page 170

Advertising
background image

DK424 Release 4.0 Upgrade Programming Example

–––––––––––––––––––––––––––––––––––––––––––––––––––

160

DKAdmin/DKBackup

Program *33

If the Back Room telephone (PDN 119) is programmed as the Owner of PhDN 500, the data in
Program

*

33 must shift:

Programs 39, 29, *29, and 59

When a port number shifts from XXX to YYY during an Release 4.0 upgrade, the following
Program changes must be made:

In Program 39, the data set for port XXX must be copied over the data set for port YYY.

In all Telephone/Console button programs, the appearances of the XXX port PDN/SDN
Button (##XXX) and DSS Button (#XXX) must be changed to ##YYY and #YYY,
respectively, on all keystrips.

Example: The Front Office Telephone changes from port 012 to port 008 during the
Release 4.0 upgrade (see

Figures 33

and

34

).

As shown below, all the button functions of the Front Office Telephone do not change after the
upgrade, but the Program 39 codes for PDN, SDN and DSS buttons change if the associated
PDN/SDN or DSS port shifts. Also PhDN, Speed Dial, and Feature button codes do not
change when ports shift.

Programs *42-1 and *42-2

Although this example does not include an RDTU (T1) PCB, it should be noted that these
programs require an RDTU slot number entry with DK Release 4.0. DK Admin/DK Backup
automatically inserts the correct slot number for these programs during the upgrade process.

Before the Upgrade

After the Upgrade

PhDN Port 500 is owned by Port 019

PhDN Port 500 is owned by Port 015

10-Button Keystrip for Front Office

Telephone on Port 012 -Before Upgrade

10-Button Keystrip for Front Office

Telephone on Port 008 -After Upgrade

Key No.

Code

Name

Key No.

Code

Name

K10

497

SDS

K10

497

SDS

K09

498

DND

K09

498

DND

K08

*103

SD103

K08

*103

SD103

K07

*102

SD102

K07

*102

SD102

K06

*101

SD101

K06

*101

SD101

K05

#017

DSS117

K05

#013

DSS117

K04

##500

PhDN 500

K04

##500

PhDN 500

K03

##019

SDN 119

K03

##015

SDN 119

K02

#000

DSS100

K02

#000

DSS100

K01

##012

PDN 112

K01

##008

PDN 112

Advertising