13 kit contents, em430fx137rf900, 14 hardware installation, msp-fet430pif – Texas Instruments MSP430 User Manual

Page 19

Advertising
background image

www.ti.com

Kit Contents, EM430Fx137RF900

Table 1-2. Individual Kit Contents, MSP-TS430xx (continued)

Target Socket

Socket Type

Supported Devices

Included Devices

Headers / Comment

Module

100-pin PZ

Eight PCB 1×25-pin headers (four

MSP-TS430PZ100B

MSP430F67xx

2 x MSP430F6733IPZ

(QFP ZIF)

male and four female

MSP-

100-pin PZ

MSP430F543x,MSP430

Eight PCB 1×25-pin headers (four

2 x MSP430F5438IPZ

TS430PZ5x100

(QFP ZIF)

BT5190IPZ

male and four female

MSP-

100-pin PZ

Eight PCB 1×25-pin headers (four

MSP430F663x, 'F563x

2 x MSP430F6638IPZ

TS430PZ100USB

(QFP ZIF)

male and four female

See the device data sheets for device specifications. Device errata can be found in the respective device
product folder on the web provided as a PDF document. Depending on the device, errata may also be
found in the device bug database at

www.ti.com/sc/cgi-bin/buglist.cgi

.

1.13 Kit Contents, EM430Fx137RF900

One READ ME FIRST document

One legal notice

One MSP430 CD-ROM

Two target socket module
MSP-EM430F5137RF900: Two EM430F5137RF900 target socket modules. This is the PCB on which
is soldered a CC430F5137 device in a 48-pin RGZ package. A 2×7-pin male connector is also present
on the PCB
MSP-EM430F6137RF900: Two EM430F6137RF900 target socket modules. This is the PCB on which
is soldered a CC430F6137 device in a 64-pin RGC package. A 2×7-pin male connector is also present
on the PCB

Two CC430EM battery packs

Four AAA batteries

Two 868-/915-MHz antennas

Two 32.768-kHz crystals

18 PCB 2×4-pin headers

1.14 Hardware Installation, MSP-FET430PIF

Follow these steps to install the hardware for the MSP-FET430PIF tools:

1. Use the 25-conductor cable to connect the FET interface module to the parallel port of the PC. The

necessary driver for accessing the PC parallel port is installed automatically during CCE/CCS or IAR
Embedded Workbench installation. Note that a restart is required after the CCE/CCS or IAR
Embedded Workbench installation for the driver to become active.

2. Use the 14-conductor cable to connect the parallel-port debug interface module to a target board, such

as an MSP-TS430xxx target socket module. Module schematics and PCBs are shown in

Appendix B

.