3.11Error Codes and Description

3 Diagnostic Programs

TECRA S1Maintenance Manual

59

01

Read Error

The ROM BIOS has Physical
problems.

Test this unit on multiple
machines.

02

Write-Protect Error

The ROM BIOS has Physical
problems.

As above.

03

Base Memory Error
Address

The test pattern read out from the
base memory is different from
the one that has been written in
this address.

Test this memory chip on
multiple machines.

04

(XMS)Memory Problem

The test pattern read out from the
extension memory is different
from the one that has been
written in this address.

As above.

05

(XMS) Out Of Range

Wrong parameters setup.

Check and reset the parameters.

06

Address Test Error

Interference between different
address channels.

Test this memory chip on
multiple machines.

07

Toggle Bit Error

Errors with the timer chip.

As above.

08

Interval Error

The acquired refreshing
frequency is out of the estimated
range.

Reset the estimated range.

09

L1 Cache test Error

The pattern read out from the L1
Cache is different from the one
that has been written in the same
address.

Test this unit on multiple
machines.

12 Data Bus Error

Interference between different
data channels.

As above.

14

Speed

Error

Failure during the transfer speed
test.

As above.

03xx

Board

01

DMA Test Error

DMA channel can not transfer
data normally.

Repeat multiple times. Whether
there is always the same error,
replace the board.

04

Interval Timer Error

The difference between the
actual precision of the interval
timer and its theory value is out
of the permitted range. The timer
counts imprecisely.

As above.

05

Periodic Faster Error

The frequency is beyond the
standard.

As above.

06

Periodic Slower Error

The frequency is below the
standard.

As above.