3 Diagnostic Programs 3.11Error Codes and Description

62

TECRA S1Maintenance Manual

26

8bits Video Mode Test
Error

As above.

As above.

27

15bits Video Mode Test
Error

As above.

As above.

28

16bits Video Mode Test
Error

As above.

As above.

29

24bits Video Mode Test
Error

As above.

As above.

30

32bits Video Mode Test
Error

As above.

As above.

31xx

Audio

01 Audio Play Fail

Cannot play music.

Check the Audio connection,
replace the external fixture, and
repeat the test.

02 Record Fail

Cannot record.

As above.

11xx

LPT

01 Data Register Error

The data register can not perform
normally.

Check the external fixture and
BIOS setup, and repeat the test.

02 Control Register Error

The control register can not
perform normally.

As above.

03

Does not Support ECP
Mode(Ver3.20)

LPT does not support ECP mode.

Check the BIOS setup, and repeat
the test.

04 FIFO Test Error

LPT cannot perform normally
under FIF0 TEST mode (ECP
internal mode).

As above.

05 IRQ Active Error

1.LPT IRQ cannot be activated.
2. The external fixture does not
match with the chosen version.

Check the external fixture and
BIOS setup, and repeat the test.

06 No Fixture On The Port No external fixtures on LPT port. As above.

09

CTR/STR Connection
Error

1. There is OC (Open Circuit) or
SC (Short Circuit) on the LPT
port CTR/STR.2. The external
fixture does not match with the
chosen version.

Check the external fixture and the
port pins, and repeat the test.

10

DTR/STR Connection
Error

As above.

As above.

11 Toshiba Fixture Error

As above.

As above.

12 No Paper

No papers in the printer.

Check for papers in the printer.