Toshiba TECRA S1 User Manual

Page 138

Advertising
background image

3 Diagnostic Programs 3.11Error Codes and Description

64

TECRA S1Maintenance Manual

12

Modem Status Change
Interrupt Error

The Modem Status Change
Interrupt cannot be invoked.

As above.

13

FIFO Disable Over Time
Error

1) UART version is below 16550
and does not support FIFO.
2) COM PORT FIFO does not
perform normally.

1) Whether the COM PORT does
not support FIFO, this test should
be ignored.
2) Check for the external fixture
on the COM PORT;
3) Try with other test software;
4) Replace the SUPPER IO chip.

14 FIFO Cannot Enable Error As above.

As above.

15

FIFO Touch off Over
Time Error

As above.

As above.

16

Data Received Check
Error

The Data Receive Check of
COM PORT does not perform
normally.

1) Check for the external fixture
on the COM PORT;
2) Try with other test software;
3) Replace the SUPPER IO chip.

17 Data Receive Error

The Data Receive of COM
PORT does not perform
normally.

1) Try with other test software;
2) Replace the SUPPER IO chip.

18

RTS-CTS Connection
Test Error

There is OC with the RTS-CTS
pins.

1) Check whether the external
fixture of correct version is
connected.
2) Try with other test software;
3) Replace the SUPPER IO chip.

19

DTR-DSR Connection
Test Error

There is OC with the DTR-DSR
pins.

As above.

08xx

LAN

Card

01

PCI bus Error during
device ID test

Don’t Scan PCI device

Don’t support PCI BIOS

02

PCI Ethernet card not
present during device ID
test

Don’t find Net card

Please insert Net cad

03

Intel PCI Ethernet card
not present during MAC
test

Don’t found Net Card, This Card
can’t be Read MAC by this
method

Please update netcard or use other
method

09xx

Keyboard

01

Keyboard Map & Stroke
Test Fail

Keyboard Map & Stroke Test
fails.

Check the KBD connection and
repeat the test.

02

LED Flash Test Fail

LED Flash test fails.

As above.

03

Clock Line Test Fail

Clock Line Test fails.

As above.

Advertising