Appendix 6 - soft starter settings record – Toshiba 18 - 1250 A User Manual

Page 94

Advertising
background image

TE Series

Digital Solid State Soft Starters 18 – 1250A

87

Appendix 6 - Soft Starter Settings Record

The following chart may be used to record the changes made to the factory settings.

Fn # Group

Function Description

Adjustment / Display Range

Setting

Increments

Factory

Setting

Setting Setting

F001

M

o

to

r an

d

O

v

e

rlo

a

d

In

fo

.

Motor Nameplate FLA

FLA must be programmed for
starter to function.

50-100% of Max Amp Rating.
Upper limit of range automatically
adjusts downward as Service factor
is increased.

1 amp

0

F002

Motor Nameplate
Service Factor

1.00 - 1.30 SF

0.05

1.0 SF

F003

Overload Class During Start

NEMA / UL Class 5 - 20

5

Class 10

F004

Overload Class During Run

NEMA / UL Class 5 - 30

5

Class 10

F005 Overload

Reset

0 = Manual
1 = Auto
2 = Disabled Overload

1

0

(Manual)

F006-9

Reserved for factory use

F010

Startin

g

an

d St

oppi

ng M

ode

s

Ramp Type Selection

VR = Voltage Ramp
CR = Current PID Ramp
1 = Ramp 1, 2 = Ramp 2

Setting 1 = VR1 + VR2
Setting 2 = CR1 + CR2
Setting 3 = VR1 + CR2
Setting 4 = CR1 + VR2

1

1

VR1+VR2

F011

Initial Torque (VR) of Ramp 1

0-100% Line Voltage

1%

60%

F012

Initial Torque (CR) of Ramp 1

0-600% Motor

Current

1% 200%

F013

Accel Ramp Time of Ramp 1

1-120 seconds

1 second

10

seconds

F014

Max Current Limit of Ramp 1

200 - 600% Motor

Current

1% 350%

F015

Initial Torque (VR) of Ramp 2

0-100% Line Voltage

1%

60%

F016

Initial Torque (CR) of Ramp 2

0-600% Motor

Current

1% 200%

F017

Accel Ramp Time of Ramp 2

1-120 seconds

1 second

10

seconds

F018

Max Current Limit of Ramp 2

200 - 600% Motor

Current

1% 350%

F019

Jog M

odes

Voltage Jog

5 – 100% Line Voltage

1%

50%

F020

Time of Voltage Jog

1 – 20 Seconds

1 second

10

seconds

F021

Current Jog

100 – 500% Motor

Current 1%

150%

F022

Kick

Mode

Kick Start Voltage

0 = Disabled, or
10 - 100% Line Voltage

1%

0

Disabled

F023

Kick Start Time

0.1 - 2 Seconds

0.1second

0.8 sec

Advertising