TE Series

Digital Solid State Soft Starters 18 – 1250A

89

Fn # Group

Function Description

Adjustment / Display Range

Setting

Increments

Factory

Setting

Setting

Setting

F040

Current

an

d Gr

oun

d Fa

ult Pr

ot

ectio

n

Current Imbalance Trip

0 = Disabled, or
5 - 30% imbalance

1%

0

Disabled

F041

Current Imbalance Trip Delay

1 - 20 seconds

1 second

2

seconds

F042

Over Current Trip

0 = Disabled, or
100 - 300% of motor FLA

1%

0

Disabled

F043

Over Current Trip Delay

1 - 20 seconds

1 second

1 second

F044

Under Current Trip

0 = Disabled, or
10 - 90% of motor FLA

1%

0

Disabled

F045

Under Current Trip Delay

1 - 60 seconds

1 second

2

seconds

F046 Ground

Fault

Trip

0 = Disabled, or
5 - 90% of CT ratio from Fn 74

1%

0

Disabled

F047

Ground Fault Trip Delay

1 - 60 seconds

1 second

2

seconds

F048

Lock

out

s, Rese

t and

Int

e

rnal Pr

otec

tion

Coast Down (Back Spin)
Lockout Timer

0 = Disabled, or 1 - 60 minutes

1 minute

0

Disabled

F049

Maximum Starts per Hour

0 = Disabled, or 1 – 10 starts

1

0

Disabled

F050

Minimum Time Between
Starts

0 = Disabled, or 1 - 60 minutes

1 minute

0

Disabled

F051

Internal Protection Settings

1 – 127
See 5.6.9.a

1

127

Enable all

F052

Auto Reset
on Selected Faults

Fault Preferences 1 – 12
See 5.6.9.b Fault Reset Selection
Table

1

4:

Phase

Loss only

F053

Auto Reset Attempts

0 = Disabled, or 1-10 attempts

1

1

F054

Restart Delay Time Value
Readout (for F028)

0-999 Minutes

1

0

F055

Coast Down Timer Value
for F048

1-3600 Seconds

1

0

F056

Starts Per Hour Timer Value
for F049

1-3600 Seconds

1

0

F057

Starts Per Hour
For F049

1-10 Starts

1

0

F058

Time Value Between Starts
for F050

1-3600 Seconds

1

0

F059

Thermal Capacity to Start
for F005

0-100 % Thermal Capacity

1

0

F060

Ou

tpu

t Rel

ays

Aux Relay 1 setting

Operation # 1 – 26: see
”Aux. Relay Settings Chart”

1 1

F061

Aux Relay 2 setting

Operation # 1 – 26: see
”Aux. Relay Settings Chart”

1 2

F062

Aux Relay 3 setting

Operation # 1 – 26: see
”Aux. Relay Settings Chart”

1 16

F063

Aux. Relay Delay Timer
(for Operations 22-26)

0 (Disabled), or 1-999 seconds

1 second

0

No Delay

F064

Reserved for factory use

Advertising