Rear panel sw1 switch, 1 resistive programming of output voltage, 2 resistive programming of output current – Xantrex Technology XFR 2800 User Manual

Page 22: 3 selects output voltage programming source range, 5 selects output voltage monitor range, 6 selects output current monitor range, 7 selects remote shutdown logic, 8 selects over temperature shutdown reset mode, Figure 1.3 programming and monitoring sw1 switch, Switch is shown in factory default configuration.)

Advertising
background image

Features and Specifications
Rear Panel Connectors and Switch

20

Operating Manual for XFR 2.8kW Series Power Supply

Rear Panel

SW1 Switch

The SW1 Programming, Monitoring, and Shutdown Select switch is an 8-position
piano DIP switch located on the power supply’s rear panel. See Figure . The SW1
switch enables you to choose:

Resistive programming of output voltage or current limit

Output voltage and current limit programming scales

Output voltage and current monitor scales

Remote shutdown circuit logic

Over temperature shutdown mode

Figure 1.3 Programming and Monitoring SW1 Switch

(Switch is shown in factory default configuration.)

Table 1.2 shows the functions assigned to each SW1 switch.

1

Resistive Programming of Output Voltage

2

Resistive Programming of Output Current

3

Selects Output Voltage Programming Source Range

4

Selects Output Current Limit Programming Source Range

5

Selects Output Voltage Monitor Range

6

Selects Output Current Monitor Range

7

Selects Remote Shutdown Logic

8

Selects Over Temperature Shutdown Reset Mode

Advertising