Rear Panel Connectors and Switch

24

Operating Manual for XFR 2.8kW Series Power Supply

Making J2 Connections

Make connections to the J2 connector using its screw-type wire clamps. Before
making any connections, turn the power supply OFF and wait until the front panel
displays have gone out. You can unplug the connector from the back of the unit in
order to make it easier to install the required wiring.

Wiring

For most connectors and jumpers, use any suitable wire such as 16 to 24 AWG
stranded wire. For lowest noise performance, use shielded pair wiring. Strip wires
0.26 in. (6.5 mm), insert, and tighten the wire clamp.

!

CAUTION
Do not attempt to bias program/monitor signal return (J2 terminals 5, 7, 9, and
11) relative to the supply output because control ground (J2-3) and the
program/monitor signal returns are at the same potential as the power supply
return in a standard unit. Use the Isolated Programming (ISOL) Interface option
to allow control from a programming source at a different potential relative to the
supply’s output.

!

CAUTION
To maintain the isolation of the power supply output and prevent ground loops,
use an isolated (ungrounded) programming source when operating the power
supply via remote analog control at the J2 connector.

WARNING
There is a potential shock hazard when using a power supply with a rated output
greater than 40 V. Use wiring with a minimum insulation rating equivalent to the
maximum output voltage of the power supply. For example, select TEW-105,
105 °C, 600 V wiring for use with a 600 V, 4 A model power supply.