Figure 3.1 Operating Modes

Constant Voltage Mode Operation

The power supply will operate in constant

voltage mode whenever the load current I

L

is less than the current limit setting I

SET

,

or: I

L

< I

SET

(Note: I

L

= V

SET

/ R

L

)

In constant voltage mode, the power supply maintains the output voltage at the
selected value (V

SET

) while the load current I

L

varies with the load requirements.

Constant Current Mode Operation

The power supply will operate in constant

current mode whenever the load resistance is low enough that the load current I

L

is

equal to the current limit setting I

SET

(Note: V

L

=I

SET

R

L

)

In constant current mode, the power supply maintains the output current at the
selected value (I

SET

) while the load voltage varies with the load requirements.

Automatic Mode Crossover

This feature allows the power supply to

automatically switch operating modes in response to changing load requirements. If,
for instance, the power supply was operating in Constant Voltage Mode (I

L

< I

SET

),

and the load changed so that the load current (I

L

) became equal to the current limit

setting (I

SET

), the power supply would automatically switch into Constant Current

Mode and the output voltage would vary in response to changes in load current. If
the additional load was subsequently removed so that the load current was again less
than
the current limit setting, the supply would automatically return to Constant
Voltage Mode.

Output
Voltage

Constant Voltage
Mode Region

V

SET

0

0

I

SET

Output
Current

R

L

V

SET

I

SET

Crossover Point R

L

V

SET

I

SET

R

L

V

SET

I

SET

Constant Current
Mode Region

Where

R

L

V

SET

I

SET

Load Resistance

Output Voltage Setting

Output Current Limit Setting