Shipped configuration (local control mode), Table 3.1 – Xantrex Technology XFR 2800 User Manual

Page 61

Advertising
background image

Local Operation

Standard Operation

Release 2.1

59

Shipped

Configuration

(Local Control

Mode)

The factory ships units already configured for local control (front panel) operation.
See Table 3.1 for a summary of this configuration. See Figure 1.1 and Figure for
front and rear panel diagrams.

Table 3.1 Shipped Configuration (Local Control Mode)

Local Control Configuration

Additional References

Use the front panel controls to adjust the
output voltage and current limit settings.
(Note: Use the LOCAL button only when you
have a digital programming interface
installed.)

See Section 3 for front panel operation.
See Section 4 for remote analog
programming procedure(s).

The supply's sense point is at the rear panel
J10 sense connector terminals.

See

“Local and Remote Sensing” on

page 53

for how to change from local to

remote sensing.

The OVP set point is adjusted at the front
panel to approximately 110% of rated output
voltage.

See

“Using Over Voltage Protection

(OVP)” on page 61

for the adjustment

procedure.

The over temperature shutdown function
automatically resets when activated as
determined by the position of rear panel
switch SW1-8. A latch off setting is also
available.

See

“Over Temperature Protection

(OTP)” on page 70

for more

information about switch SW1-8
settings.