Section 3. Local Operation

Introduction

Once you have installed the power supply and have connected both the AC input
power and the load as covered in Section 2. Installation, the power supply is ready
to operate in local control mode (that is, operation at the unit’s front panel).

See “Standard Operation” on page 57 for a brief explanation of Constant Voltage

and Constant Current Mode operation and see page 61 to page 70 for more about

power supply functions such as over voltage protection, shutdown function, over

temperature protection, and using multiple supplies.

See “User Diagnostics” on page 71 for troubleshooting information for the

operator.

Turn to Section 4. Remote Operation for descriptions of remote programming

options and remote monitoring of the power supply.

Standard Operation

This power supply has two basic operating modes: Constant Voltage Mode and
Constant Current Mode, and two control modes: Local Control Mode (default
setting) and Remote Programming Mode. Both operating modes are available
regardless of which control mode is used.

Operating

Modes and

Automatic

Crossover

Whether controlled by local or remote programming, the power supply has two basic
operating modes: Constant Voltage Mode and Constant Current Mode. The mode in
which the power supply operates at any given time depends on the combination of:

output voltage setting V

SET

output current limit setting I

SET

resistance of the attached load R

L

See Figure 3.1 for a graphical representation of the relationships between these
variables.