Sensing for Parallel Operation

Use default local sensing to enhance power

sharing between units, as the impedance of the load lines will tend to correct for
current imbalance. If you use remote sensing at the load for better voltage regulation,
one supply always operates in current limit mode and supplies most of the power.

Figure 3.3 Parallel Operation of Multiple Supplies

(Local sense lines shown are default J10 connections.)

Configuring

Multiple

Supplies for
Split Supply

Operation

Split supply operation uses two power supplies to obtain two positive voltages with
a common ground, or to obtain a positive-negative supply.