Autoflow Operation

Dryer Control Panel Featuring the

Electronic Monitoring Control System

The control panel provides easy access to gauges

and controls, and the illuminated switches provide a

quick reference for every operating function. The

patent pending Electronic Monitoring Control

System is a computerized control system that gives

instant information regarding dryer operation.

Moisture Control Thermostat

This electronic thermostat controls the moisture

level of discharged grain by sensing grain column

temperature using the four (4) RTD temperature

sensors located in the drying chamber. The moisture

control thermostat indicates the current grain

temperature in the drying chamber with LEDs. The

grain temperature setpoint is set on the moisture

control thermostat. In the Autoflow mode, when the

grain temperature reaches the grain temperature

setpoint, and the dry timer has reached zero, the

dryer will dump the third driest portion of grain

from the drying chamber into the storage chamber.

In the Autobatch mode the dryer will dump all of the

grain into the storage chamber.

Moisture Control Switch

This switch turns the power on or off to the moisture

control thermostat. When placed in the “on”

position, the dryer will not enter the dump cycle

until the grain temperature has reached the grain

temperature setpoint on the moisture control thermo-

stat and the dry timer has reached zero. When

placed in the “on” position, the moisture control

switch lights up when the grain temperature is below

the grain temperature set point on the moisture

control thermostat. When placed in the “off”

position, the dryer ignores the grain temperature and

operates strictly off the dry timer. When placed in

the “off” position, the moisture control switch does

not light up.

Control Power Switch

The power to the Electronic Monitoring Control

System is turned on or off with the control power

CONTROL SYSTEM

switch. The switch lights up when placed in the

“on” position. If the switch is placed in the “on”

position, and the light does not light up, make sure

that the emergency stop switches located on the

Autoflow control box is pulled out.

24-Volt Power Switch

This switch turns the power on or off to the actuator

control box. The switch lights up when placed in the

“on” position. If the switch is placed in the “on”

position, and the light does not light up, make sure

that the emergency stop switch located on the

actuator control box is pulled out (1997 model only).

Aeration Fan Switch

This switch controls the operation of the aeration fan

located at the bottom of the bin. The switch lights

up when the aeration fan comes on. When placed in

the “auto” position, the aeration fan starts and stops

with the main drying fans. When placed in the “off”

position, the aeration fan will not run. When placed

in the “on” position, the aeration fan comes on when

the dryer is running.

Load Auger Switch

This switch controls the operation of the fill

system(s) that load grain into the drying chamber.

The switch lights up when the fill system(s) are

running. When placed in the “auto” position, the fill

system(s) start and stop automatically depending on

the level of grain relative to the drying chamber high

level rotary switch. When operating in the

Autobatch mode, the fill system(s) will shut off 2/3

(two-thirds) of the way through the dry cycle, even

if grain has not reached the drying chamber high

level rotary switch. When placed in the “off”

position ,the fill system(s) will not run. When

placed in the “on” position, the fill system(s) come

on and stay on when the dryer is running.

Fan Switch

This switch controls the operation of the main

drying fan(s). The switch lights up when the

airswitch located in the sidewall next to the master