Terminology – Grain Systems PNEG-728 User Manual

Page 39

Advertising
background image

39

Autoflow Operation

TERMINOLOGY

Linear Actuator-The linear actuator is attached to

the cable that controls the dump chutes. When the

dryer enters into the dump cycle the linear actuator

extends giving slack to the dump chute cable.

When slack is given to the dump chute cable the

dump chutes open dumping grain from the drying

chamber into the storage chamber. The linear

actuator is located in the actuator control box.

Load Delay-The load delay is not used in single

fill systems. The load delay is located on the dryer

control panel next to the display screen. The load

delay controls how long fill system #2 runs after

grain has reached the chamber high level rotary

switch in units with two fill systems.

Low-Fire-Low-fire is the state the burner is in

when the plenum temperature meets or exceeds the

cycle setpoint on the hi-lo thermostat. When the

unit is in low-fire the plenum temperature should

be declining. When the unit is in low-fire the gas

pressure should be set around 5 lbs. for liquid

propane and 2 lbs. for natural gas. The gas pres-

sure required to make the temperature fall in the

plenum may vary with ambient air conditions.

Master Drying Fan-The master drying fan is

located on the fan platform just beneath the drying

chamber on the outside of the bin and is used to

force heated air through the grain to dry it. The

master drying fan is the only fan and heater in a

single fan unit. In two fan units the master drying

fan is the fan and heater with airswitch and hi-lo

thermostat.

Moisture Control Thermostat-The moisture

control thermostat is located on the dryer control

panel. The moisture control thermostat uses four

temperature sensors located in the drying chamber

to sense the grain temperature. The grain tempera-

ture setpoint is set on the moisture control thermo-

stat.

Out of Grain Timer-The value set on the out of

grain timer is the amount of time that grain has to

reach the drying chamber low level rotary switch

when the dryer is refilling after the dump cycle in

an Autobatch system. When the dump cycle is

complete the out of grain timer begins to count

down. If grain does not reach the drying chamber

low level switch before the out of grain timer

reaches zero the dryer will give an out of grain

error and shut down. The out of grain timer is not

used in an Autoflow system. The out of grain

timer is located on the dryer control panel next to

the display.

Plenum Temperature-The plenum temperature

is the temperature of the air coming out of the fan

and heater unit(s) that is being forced through the

grain in the drying chamber. The plenum tem-

perature is sensed by the hi-lo thermostat.

Purge Delay-The purge delay is a built-in delay

used to prevent the ignition of the burner with

raw gas in the bin. After proof of airflow has

been established the computer starts counting

down the purge delay to allow the fans to dis-

perse any gases that may have accumulated in the

bin before igniting. When the purge delay

reaches zero the burner ignites and the drying

begins. The purge delay is not set by the user.

Slave Drying Fan-The slave drying fan is not

present in single fan units. In two fan units the

slave drying fan is the fan and heater without the

airswitch and hi-lo thermostat.

Storage Chamber-The storage chamber is the

chamber where grain is cooled and stored. Hot

dry grain is dumped from the drying chamber into

the storage chamber during the dump cycle. A

rotary switch warns the computer when the

storage chamber is full.

Storage Chamber High Level Rotary Switch-