Autoflow Operation

16

Setting the Load Delay

The value set on the load delay is the amount

of time that fill system number two runs after grain

reaches the drying chamber high level rotary switch.

This delay is not used with only one fill system con-

trolled by the Autoflow. The load delay should be set

long enough so that the drying chamber high level

rotary switch is covered with enough grain that the fill

system do not start and stop frequently in the dry cycle

due to settling or shrinkage; but, the load delay should

be set short enough so that grain does not reach the

drying chamber overflow rotary switch. The load

delay is set using the same procedure as the dry and

unload timers, but the reset button does not need to be

pressed to enter the new values into memory immedi-

ately.

Setting the Aux. 1 Delay

In units that the Autoflow controls one fill

system, the value set on the aux. 1 delay is the amount

of time that fill system number one runs after grain

reaches the drying chamber high level rotary switch.

The aux.1 delay should be set long enough so that the

drying chamber high level rotary switch is covered

with enough grain that the fill system does not start and

stop frequently in the dry cycle due to settling or

shrinkage; but, the aux. 1 delay should be set short

enough so that grain does not reach the drying chamber

overflow rotary switch.

In units that the Autoflow controls two fill

systems, the value set on the aux. 1 delay is the amount

of time that fill system number one runs after fill

system number two shuts off. Fill system number one

is the fill system that directly puts grain in the drying

chamber. The aux. 1 delay should be set long enough

so that all grain present in fill system number one is

loaded into the drying chamber before it shuts off.

This will decrease the current required to start fill

system number one the next time the dryer calls for

grain. The aux. 1 delay is set using the same procedure

as the dry and unload timers, but the reset button does

not need to be pressed to enter the new values into

memory immediately.

Setting the Unload Delay

The value set on the unload delay is the

amount of time that both fill system number one

and fill system number two run after grain falls

away from the wet supply rotary switch before the

unit shuts down and gives a wet supply hopper

“empty” error. In units that the Autoflow controls

only one fill system, the value set on the unload

delay is the amount of time that fill system number

one runs after grain falls away from the wet supply

rotary switch. The unload delay should be set long

enough so that the fill system(s) clean out before

the dryer shuts down; but, should be set short

enough to avoid running the fill system (s) empty

for an excessive amount of time. The unload delay

is set using the same procedure as the dry and

unload timers, both the reset button does not need

to be pressed to enter the new values into memory

immediately.

Setting the Aux. 2 Delay

The aux. 2 delay is not currently being

used.

Viewing operation time and total cycles

The total operation time and total cycles

can be viewed at any time the dryer is in the main

drying screen by pressing the increase button.

Diagnostics Mode-Resetting Batch Counter

The Electronic Monitoring Control System

can perform a self-diagnostic exam. With the dryer

stopped and in the main drying screen, press and

hold down the reset button for several seconds.

After the self-diagnostic exam is complete, the

display will read the results of the exam and will

then give the user the option to reset the batch

counter. The batch counter can be cleared by

pressing the reset button or left as-so by pressing

the enter button. After choosing an option, the user

is taken to the shutdown history retrieval. To view

past shutdowns and the time and date the shutdown

occurred, press the decrease button. Press the enter

button at any time to return to the main drying

screen.

CONTROL SYSTEM