31

Autoflow Operation

tape measure to measure the stroke on the linear

actuator. The stroke should be between 12” and

14”. If the stroke on the actuator is not 12” to 14”,

the actuator should be adjusted. Make sure that all

pulleys and cables are able to move freely when

the actuator is moving. With the actuator ex-

tended, enter the storage chamber. View each

dump chute individually. Make sure that each

dump chute opened completely when the actuator

extended. If a dump chute does not open com-

pletely, the double nuts on the bolt that the chutes

hinge on, needs to be loosened. The dump chutes

should hinge smoothly. After the chutes have

been inspected turn the dump switch on the

Autoflow control box to the “Auto” position and

press the stop switch. The chutes should raise.

Power Start Button

Before the dryer start button is pushed,

make sure there is grain in the wet supply tank. If

there is no grain in the wet supply tank, the dryer

will not start. Push the dryer start button. The

screen should no longer be flashing “STOPPED”.

Fuel Check

If using LP gas, make sure the tank has

plenty of fuel. If using natural gas, make sure

adequate supply is available. If using LP gas,

slowly open the main fuel supply valve at the tank.

If using natural gas, turn on the valve along the

supply line. Then open the ball valve on the fan

heater unit(s). Inspect all gas lines and connec-

tions for possible leaks. Any gas leaks need to be

fixed immediately!

Fan

Make sure that the fan and heater service

switches on the main drying fan(s) are in the “on”

position. Bump the fan switch on the Autoflow

control box and observe the fan rotation. The fan

should run counterclockwise. Sometimes on three

phase models the motor will run backwards. This

can easily be reversed by first turning off the

power at the main disconnect, then interchanging

any two of the three power supply wires coming

into the motor starter in the fan control box.

Reverse the two outside wires, L1 and L3, and

leave the middle one in the same position. If the

dryer is empty, the unit will not operate. The fans

cannot create enough static pressure to engage the

airswitch. You will receive a loss of airflow

message.

Aeration Fan

Bump the aeration fan switch on the

autoflow control box and observe the aeration fan

rotation. The aeration fan should run counter-

clockwise. Sometimes on three phase models the

motor will run backwards. This can easily be

reversed by first turning off the power at the main

disconnect, then interchanging any two of the three

power supply wires coming into the motor starter

in the fill system control box. Reverse the two

outside wires, L1 and L3, and leave the middle one

in the same position.

Fill System

Prepare the wet storage tank to deliver

grain to the dryer. Make sure all personnel are

away from any machinery that is controlled by the

Autoflow. Place the load auger switch in the

“Auto” position. The fill system(s) should begin

to load grain from the wet supply tank to the dryer.

When the display on the Autoflow control box

reads “GRAIN LOW LEVEL YES”, close the

valve that supplies the fill system(s) with wet grain

from the wet supply tank. After the fill system(s)

have cleaned out, place the load auger switch in

the “off” position.

Airswitch

Place the fan and heater service switches

on the main drying fan(s) in the “off” position.

Place the fan switch on the Autoflow control box

FILL SYSTEM CONTROL BOX

Advertising