Autoflow Operation

Auxiliary Fill Motor Overload

The thermal overload, in the fill system control

box for fill system number two; has tripped,

indicating an over current condition. Make sure

the emergency stop switch on the fill system

control box is pulled out as this will inhibit the

motor starter from engaging. The overload must

be reset manually. Electrically there is a loss of

12vDC on J4-16 on the input/output board.

Aeration Fan Motor Overload

The thermal overload, in the fill system

control box for the aeration fan; has tripped,

indicating an overcurrent condition. Make sure the

emergency stop switch on the fill system control

box is pulled out as this will inhibit the motor

starter from engaging. The overload must be reset

manually. Electrically there is a loss 12vDC+ on

J4-17 on the input/output board.

Autoflow Fan and Heater Control Box

The Autoflow fan and heater control box

mounted on the fan heater unit(s), houses the

motor starter, Fenwall ignition-flame detection

board, and all circuitry involved with the control of

the fan and heater unit. Two service switches are

located on the front panel of the Autoflow fan and

heater control box.

Fan

This switch allows the user to turn off the

drying fan while at the fan and heater unit. It the

Autoflow is running, and the fan is running, the

fan will stop when the fan service switch is placed

in the “off” position, but the dryer will continue

running as though the fan was on. If the burner is

running when the fan service switch is placed in

the “off” position, the burner will shut off also.

The fan service switch light on the master fan

lights up when the airswitch closes. In normal

operation the fan service switch should be left in

the “on” position.

Heater

This switch allows the user to turn off the

burner while at the fan and heater unit. If the

Autoflow is running, and the burner is running, the

burner will stop when the heater service switch is

placed in the “off” position, but the dryer will

continue running as though the burner was on.

When the heater service switch is placed in the

“off” position, the fan does NOT shut off. When

the heater service switch is placed back to the ”on”

position, the unit reignites after the purge delay.

The heater service switch light lights up when the

burner is on. In normal operation, the heater

service switch should be left in the “on” position.