Control system – Grain Systems PNEG-728 User Manual

Page 12

Advertising
background image

Autoflow Operation

12

Heater Switch

This switch controls the operation of the

burner(s). The switch lights up when the burner is

on. When the burner is on, small lights above and

below the heater switch indicate if the burner(s)

are in high fire or low fire. In the Autoflow mode,

when placed in the “auto” position, the burner(s)

fire when grain reaches the drying chamber low

level rotary switch and do not stop until the dryer

shuts down or is stopped manually by pressing the

stop switch. In the Autobatch mode, the burner(s)

shut off automatically in the cool and dump cycle.

When placed in the “off” position, the burner(s)

will not fire. When placed in the “on” position,

the burner(s) fire anytime the main drying fan(s)

are running.

drying fan senses an increase in static pressure and

closes. In the Autoflow mode, when placed in the

“auto” position, the main drying fan(s) start when

grain reaches the drying chamber low level rotary

switch and do not stop until the dryer shuts down

or is stopped manually by pressing the stop switch.

In the Autobatch mode, the main drying fan(s)

shut off automatically in the dump cycle. When

placed in the “off’ position, the main drying fan(s)

will not run. When placed in the “on” position, the

main drying fan(s) come on and stay on when the

dryer is running.

Fan Switch

This switch controls the operation of the main

drying fan(s). The switch lights up when the

airswitch located in the sidewall next to the master

drying fan senses an increase in static pressure and

closes. In the Autoflow mode, when placed in the

“auto” position, the main drying fan(s) start when

grain reaches the drying chamber low level rotary

switch and do not stop until the dryer shuts down

or is stopped manually by pressing the stop switch.

In the Autobatch mode the drying fan(s) will not

run. When placed in the “on” position, the main

drying fan(s) come on and stay on when the dryer

is running.

Dryer Control Panel, continued

Dump Switch

This switch controls the operation of the linear

actuator housed in the actuator control box. The

switch lights up when the linear actuator is mov-

ing. When placed in the “manual close position”,

the linear actuator in the actuator control box

retracts, raising the dump chutes. When placed in

the “auto” position, the linear actuator extends at

the beginning of the dump cycle- lowering the

dump chutes, and retracts at the end of the dump

cycle, raising the dump chutes. When placed in

the “manual open” position, the linear actuator

extends, lowering the dump chutes. This switch is

disabled when the dryer is running. The dryer

must be stopped to manually dump.

Dry And Hold Switch

When placed in the “on” position, the grain in the

drying chamber will not be dumped into the

storage chamber at the end of the dry cycle, and

the dryer will stop. This switch can be used to

hold the last batch of grain in the drying chamber

and stop the dryer. When placed in the “off”

position, the dryer will operate normally. The

switch lights up when placed in the “on” position.

Dryer Power Start Switch

This switch starts and operates the dryer based on

switch settings. The switch lights up when the

dryer is running. The dump switch is disabled after

this switch has been pushed.

Dryer Power Stop Switch

This switch stops all dryer functions. If an auto-

matic dryer shutdown occurs, first determine and

correct the cause of the shutdown. Press the dryer

power stop switch to reset the dryer before starting.

CONTROL SYSTEM

Advertising