Figure 7-37 Exploded view of A-frame to center collar
A
A-frame rafter assembly
C
1/2 x 1-3/4 in. flange bolt (S-10252)
B
Center collar (CTR-0347)
D
1/2 in. flange nut (S-10253)
Attaching the A-Frame to the Eave Bracket
Assemble the lower portion of the A-frame rafters to the sidewalls.
1. Install flange bolts (B) and flange nuts (D), securing one side on the A-frame assembly.
2. Repeat this procedure for the other side of the A-frame.
3. Tighten to the recommended torque specifications. See
Bolt Torque Specifications, page 26
.