Chapter 3: Hardware Requirements

Table 3-1 Hardware for 3-Post Sidewall Sheets on Bins that are 135 Ft in Diameter (cont'd.)

Gauge

Horizontal Seam

Vertical Seam

Stiffener to Sidewall

Overlap Seam

8

3/8-1 (22)

3/8-1 (48)

3/8-1.5 (12)

3/8-1.5 (2)

6

3/8-1.5 (22)

3/8-1.5 (48)

3/8-1.5 (12)

3/8-1.5 (2)

5

3/8-1.5 (22)

3/8-1.5 (48)

3/8-1.5 (12)

3/8-1.5 (2)

11L

3/8-1.5 (22)

3/8-1.5 (48)

3/8-1.5 (12)

3/8-1.5 (2)

10L

3/8-1.5 (22)

3/8-1.5 (48)

3/8-1.5 (12)

3/8-1.5 (2)

9L

3/8-1.5 (24)

7/16-2.5 (48)

3/8-1.5 (24)

3/8-2 (6)

8L

3/8-1.5 (24)

7/16-2.5 (48)

3/8-1.5 (24)

3/8-2 (6)

6LF

7/16-2 (20)

7/16-2.5 (72)

3/8-2 (24)

7/16-2 (10)

Bolt Torque Specifications

The specification torque table below will help the installer determine how tight a specific bolt must be. A
bolt that has been over tightened can be just as dangerous as one that hasn't been tightened enough.

IMPORTANT: Bolts should not be tightened in excess of the torque specifications chart listed below.

Bolt

Minimum Torque

Maximum Torque

Sealing Joints

(joints with seal-

ing washers)

Structural Joints

(joints without

any sealing

washers)

Sealing Joints

(joints with seal-

ing washers)

Structural Joints

(joints without

any sealing

washers)

ft-lb

N-m

ft-lb

N-m

ft-lb

N-m

ft-lb

N-m

5/16-18 JS Gr 8 with seal

20

27

—

—

25

34

—

—

3/8 -16 JS Gr 8 with seal

30

41

—

—

35

47

—

—

7/16-14 JS Gr 8 with seal

50

68

—

—

60

81

—

—

3/8–16 YDP Gr 8 flanged

—

—

40

54

—

—

45

61

7/16–14 YDP Gr 8 flanged

—

—

65

88

—

—

75

101

1/2-13 YDP Gr 8 flanged

—

—

100

135

—

—

115

155

26

Pneg-4135 135 Ft Diameter 40-Series Bin

Advertising