Installing the intake guard, Assembly & installation – Grain Systems Custom, Utility and Bulk Tank Augers PNEG-1435 User Manual

Page 20

Advertising
background image

20

PNEG-1435 6", 8" & 10" Utility & Bulk Augers

4. ASSEMBLY & INSTALLATION

Installing the Intake Guard

Note: For Utility Augers Only.

1. Slide the Intake guard onto the Auger Tube aligning the intake shaft with the bronze bushing

(Figure 4G)

.

Figure 4G

2. With the Intake Shaft inserted in the bushing make sure to leave approximately 1/2" of

clearance between the end of the Flight and the face of the bushing

(Figure 4H)

.

Figure 4H

Auger Tube

Flight

Bronze Bushing

Intake Guard

Intake Shaft

Flight

1/2" Between Bushing and Flight

Bushing