4. ASSEMBLY & INSTALLATION
Installing the Intake Guard
Note: For Utility Augers Only.
1. Slide the Intake guard onto the Auger Tube aligning the intake shaft with the bronze bushing
.
Figure 4G
2. With the Intake Shaft inserted in the bushing make sure to leave approximately 1/2" of
clearance between the end of the Flight and the face of the bushing
Figure 4H
Auger Tube
Flight
Bronze Bushing
Intake Guard
Intake Shaft
Flight
1/2" Between Bushing and Flight