Operation, Chapter 7 operation, Operate the auger – Grain Systems Custom, Utility and Bulk Tank Augers PNEG-1435 User Manual

Page 36: Warning

Advertising
background image

36

PNEG-1435 6", 8" & 10" Utility & Bulk Augers

7. OPERATION

Operate the Auger

Note: The auger capacity can fluctuate greatly under varying conditions. Moisture

content, different commodities, amount of foreign matter and speeds all play a part
in the performance of the auger. Twenty-five percent(25%) moisture may cut
capacity by as much as (40%) under some conditions.

1. Make certain there are at least two (2) people in the work area to monitor operations at all

times.

2. Visually inspect the auger periodically during operation.

Be alert for any unusual vibrations, noises and the loosening of any fasteners. If anything
unusual is detected, immediately shutdown the auger, disconnect and lockout the power
source before servicing.

3. Consideration should be given to the proper size auger for a batch drying or any intermittent

type operations. When augers are stopped and restarted under full load, it may result in
damage to the auger. Using a larger diameter auger and reducing its load level will be far
better than subjecting a smaller diameter auger to big loads. If an auger is kept from
absolute filling, it will make startup easier and will convey more efficiently.

WARNING