Intermediate well installation, N “b, Installation – Grain Systems Unload Augers PNEG-1421 User Manual
Page 15
![background image](/manuals/277898/15/background.png)
4. Installation
PNEG-1421 Direct Gear Drive Bin Sweep Auger (with Roller Wells)
15
Intermediate Well Installation
1. Cut openings in the bin floor for the intermediate wells.
.
The number of wells depends on bin size. The distances between intermediate wells and the center
well should be equal.
Figure 4D
Bin
Size
# of Intermediate
Wells
Distance from
Center of Bin
to Wall (A)
Distance Between
Center Well and First
Intermediate Well (B)
Distance Between
Wells (C)
Distance from
Center of Bin to
Angle Ring (D)
15'
1
7' - 5-1/2"
39-3/8"
*
9'-5"
18'
1
8' - 11-7/16"
36-3/4"
*
11'-5"
21'
2
10' - 5-5/16"
32-1/2"
49-3/4"
12'-5"
24'
2
11' - 11-1/4"
38-1/2"
55-3/4"
13'-11"
27'
2
13' - 5-3/16"
44-1/2"
61-3/4"
15'-5"
30'
2
14'-11"
50-1/2"
67-3/4"
16'-11"
33'
3
16' - 4-15/16"
39.563"
56.813"
18'-1"
36'
3
17' - 10-7/8"
42.563"
59.813"
19'-11"
39'
3
19' - 4-3/4"
47.063"
64.313"
21'-5"
42'
4
20' - 10-11/16"
39"
56-1/4"
23'-5"
48'
4
23' - 10-1/2"
46.2"
63.45"
26'-5"