45

6. Shut Down

Normal Shut Down

1. Before shutting down the unit, be sure the hoppers and augers are empty.

2. Disconnect and lock out the power source before leaving the work area.

Emergency Shut Down

1. Know how to shut down the auger in case of an emergency.

2. Do not restart the auger while it is under load.

3. Close the bin well control gates.

4. Reconnect and unlock the power source.

5. Clear the auger gradually, until there is no grain and there are no obstructions.

Storage Preparation

1. Close all wells to the discharge auger.

2. Position the direct gear drive sweep directly over the intermediate wells.

NOTE: Make sure that the clutch control rods are disengaged.

3. Be sure the unload tube is empty.

4. Shut down the auger.

5. Make sure all fasteners are tight.

DANGER

NEVER start the equipment under load. Doing so may cause damage. This type of
damage is considered a misuse of the equipment. Any misuse of the equipment
may void the warranty.

DANGER

DO NOT enter the grain bin unless all power driven equipment has been
shut down.