Xylem HYDROVAR (HV2.1 - 3.45) User Manual

Page 19

Advertising
background image


19

To remove the HYDROVAR – cover, open the 3 fastening screws.

o

Be careful not to lose the small gaskets!

o

Ensure that there is no water on the unit before you open the cover.

o

Be careful not to damage the connecting cable!


• Position the HYDROVAR on the motor fan cover.
• Try to centre it as good as possible using the rubber centre bit.

o

If you use a motor with plastic fan cover, you have to use a steel mounting ring.


• Install the HYDROVAR on the motor fan cover by using the mounting brackets, the four

screws and the related washers.

• Make sure the converter is well centred and then tighten the four screws.
• Tighten each fastening screw until the two bottom teeth in the brackets start to grip the

fan cover.


• After connecting the electrical components, mount the cover on the HYDROVAR and

tighten the three fastening screws.

o

Make sure of a good connection of the connecting cable and the ground wire.

o

Control the gasket of the HYDROVAR and don’t forget to install the gaskets of the
fastening screws.

o

Ensure that the mounting of the cable glands is done properly and use closing glands
for cable-bushings which aren’t used.