6.3.2 Motor connection
Mounting of the PTC

Variant A :

Variant B :



1. Open the cover of the conduit box and remove also the terminal block inside
2. Fix the PTC (Variant A or B)
3. Remounting of the terminal block
4. Electrical connection of the motor cables

The PTC should be fixed to the metal compound of the motor. This is necessary to

measure the right temperature of the motor!


The connection of the motor cable depends on the type of the motor and can be done in star-
or delta connection.
The right connection for the motor has to be selected as shown on the motor label according
to the output voltage of the HYDROVAR.

star - connection

delta - connection

U
V
W

H
Y
D
R
O
V
A
R

U

V

W

Motor block

PTC

Terminal block

Rubber gasket

Cover of the
conduit box

H
Y

D
R

O
V
A

R

PTC

PTC

U

V

W

U
V
W

PTC

Advertising