To quit the following errors you have to cut he power supply for >30 seconds. If the error

signal should appear again, contact customer service and provide a detailed description of

the error.

Internal errors

Error-message on the Display - red LED on

ERROR 1

EEPROM-ERROR
(corresponding data block
malfunction)

Reset - after repeated error-message
⇒ change control card

ERROR 2

Security error /
Software protection error

Reset - after repeated error-message
⇒ change control card

ERROR 3

RAM-error

Reset - after repeated error-message
⇒ change control card

ERROR 4

Button error
(e.g.: jammed key)

• check push buttons,
• Display-board may be defect

ERROR 5

EPROM-error

Reset - after repeated error-message
⇒ change control card

ERROR 6

Program error:
Watchdog error

Reset - after repeated error-message
⇒ change control card

ERROR 7

Program error:

Processor pulse error

Reset - after repeated error-message
⇒ change control card

ERROR 8

Program error:

invalid processor command

• check the installation of the cables,

connection of the screen and
potential equalization

• check earth/ground
• install additional inductances for

the signal-cables (e.g. ferrites)

ERROR 9

Counter of operation time

Reset - after repeated error-message
⇒ change control card