2 Transportation and Storage

2.1 Inspect the delivery

1.

Check the outside of the package for evident signs of damage.

2.

Notify our distributor within eight days of the delivery date, if the

product bears visible signs of damage.

Unpack the unit
1.

Follow applicable step:

• If the unit is packed in a carton, then remove the staples and

open the carton.

• If the unit is packed in a wooden crate, then open the cover

while paying attention to the nails and straps.

2.

Remove the securing screws or the straps from the wooden base.

2.1.1 Inspect the unit

1.

Remove packing materials from the product.
Dispose of all packing materials in accordance with local regula-

tions.

2.

Inspect the product to determine if any parts have been damaged

or are missing.

3.

If applicable, unfasten the product by removing any screws, bolts,

or straps.
For your personal safety, be careful when you handle nails and

straps.

4.

Contact the local sales representative if there is any issue.

2.2 Transportation guidelines

Precautions

WARNING:

• Observe accident prevention regulations in force.

• Crush hazard. The unit and the components can be

heavy. Use proper lifting methods and wear steel-toed

shoes at all times.

Check the gross weight that is indicated on the package in order to se-

lect proper lifting equipment.

Position and fastening
The pump or pump unit can be transported only horizontally. Make

sure that the pump or pump unit is securely fastened during transpor-

tation and cannot roll or fall over.

WARNING:
Do not use eyebolts screwed on the motor for handling the

whole electric pump unit.
Do not use the shaft end of the pump or of the motor to han-

dle the pump, the motor or the unit.

• Eyebolts screwed onto the motor may be exclusively used to han-

dle the individual motor or, in case of a not balanced distribution

of weights, to partially lift the unit vertically starting from a horizon-

tal displacement.

Pump unit must always be fixed and transported as shown in

Figure 4

,

and the pump without motor must be fixed and transported as shown

in

Figure 5

.

• Remove cover plates 681 from drive lantern 341 and cross the

lifting tackles. To transport the pump/pump set suspend it from the

lifting tackle as shown.

Unit without motor

WARNING:
A pump and motor that are purchased separately and then

coupled together results in a new machine under the Machi-

nery directive 2006/42/EC. The person making the coupling

is responsible for all safety aspects of the combined unit.

2.3 Storage guidelines

Storage location
The product must be stored in a covered and dry location free from

heat, dirt, and vibrations.

NOTICE:

• Protect the product against humidity, heat sources, and mechani-

cal damage.

• Do not place heavy weights on the packed product.

2.3.1 Long-term storage

If the unit is stored for more than 6 months, these requirements apply:

• Store in a covered and dry location.

• Store the unit free from heat, dirt, and vibrations.

• Rotate the pump shaft by hand several times at least every three

months.

Treat bearings and machined surfaces so that they are well preserved.

Refer to the drive unit and coupling manufacturers for their long-term

storage procedures.
For questions about possible long-term storage treatment services,

please contact your local sales and service representative.

Ambient temperature
The product must be stored at an ambient temperature from -5°C to

+40°C (23°F to 104°F).

3 Product Description

3.1 Pump design

The pump is a horizontal single stage pump with volute casing close

coupled to standard electric motors. The pump can be used for han-

dling:

• Cold or warm water

• Clean liquids

• Aggressive liquids which are not chemically and mechanically ag-

gressive to the pump materials.

The product can be supplied as a pump unit (pump and electric motor)

or only as a pump.

NOTICE:
If you have purchased a pump without motor, make sure that the motor

is suitable for coupling to the pump.

Intended use
The pump is suitable for:

• Water supply and water treatment

• Cooling and hot water supply in industries and building services

• Filter systems, and so on.

• Irrigation and sprinkler systems

• Drainage systems

• Heating systems

• Condensate transportation

Additional uses for optional material:

• District heating

• General industry

• Food and beverage industry

Improper use

WARNING:
Improper use of the pump may create dangerous conditions

and cause personal injury and damage to property.

An improper use of the product leads to the loss of the warranty.
Examples of improper use:

en - Translation of the original instructions