2 pump description, 3 nameplate, 4 design structure – Xylem e-NSCS User Manual

Page 14: 5 material, 6 mechanical seal, 7 application limits, 4 installation

Advertising
background image

• Liquids not compatible with the pump construction materials

• Hazardous liquids (such as toxic, explosive, flammable, or corro-

sive liquids)

• Potable liquids other than water (for example, wine or milk)

Examples of improper installation:

• Hazardous locations (such as explosive, or corrosive atmos-

pheres).

• Location where the air temperature is very high or there is poor

ventilation.

• Outdoor installations where there is no protection against rain or

freezing temperatures.

DANGER:
Do not use this pump to handle flammable and/or explosive

liquids.

NOTICE:

• Do not use this pump to handle liquids containing abrasive, solid,

or fibrous substances.

• Do not use the pump for flow rates beyond the specified flow

rates on the data plate.

Special applications
Contact the local sales and service representative in the following cas-

es:

• If the density and/or viscosity value of the pumped liquid exceeds

the value of water, such as water with glycol; as it may require a

more powerful motor.

• If the pumped liquid is chemically treated (for example softened,

deionized, demineralized etc.).

• Any situation that is different from the ones that is described and

relate to the nature of the liquid.

3.2 Pump description

See

Figure 6

for an explanation of the description code for the pump

and one example.

3.3 Nameplate

The nameplate is a metal label that is located on the bearing bracket.

The name plate lists key product specifications. For more information,

see

Figure 7

The nameplate provides information regarding the impeller and casing

material, the mechanical seal and their materials. For more informa-

tion, see

Figure 8

.

IMQ or TUV or IRAM or other marks (for electric pump only)
Unless otherwise specified, for products with a mark of electrical-relat-

ed safety approval, the approval refers exclusively to the electrical

pump.

3.4 Design structure

• Dimensions according EN 733 and additional not standardized

extension sizes

• Volute casing pump with back pull out power end

• Single stage

• For horizontal assembly

Part

Description

Casing

• Radial split volute casing with radial discharge

• Replaceable wear ring

Impeller

• Closed radial impeller with wear rings on both

sides

Shaft seal

• Single mechanical seal acc. EN 12756

• Optional cartridge mechanical seal

Bearings

• Radial ball bearings of motor

• Grease lubrication

See the sectional drawing

Figure 9

.

3.5 Material

The metallic parts of the pump that come in contact with water are

made of the following:

Standard/

Optional

Material

code

Material

casing/

impeller

EN733

range

32–125 to

150-400

Extension

range

200–250,

200–315,

250–315

Standard

CC

Cast iron /

Cast Iron

X

Standard

CB

Cast Iron /

Bronze

X

Standard

CN

Cast Iron /

Stainless

Steel

X

Standard

DC

Ductil Iron /

Cast Iron

X

Standard

DB

Ductil Iron /

Bronze

X

Standard

DN

Ductil Iron /

Stainless

Steel

X

Standard

NN

Stainless

Steel / Stain-

less Steel

X

Optional

RR

Duplex / Du-

plex

X

X

3.6 Mechanical seal

Unbalanced single mechanical seal acc. EN 12756, version K Dimen-

sions. See

Table 10

.

3.7 Application limits

Maximum working pressure
This flow chart shows the maximum working pressure depending on

the pump model and the temperature of the pumped liquid.

P

1max

+ P

max

≤ PN

P

1max

Maximum inlet pressure

P

max

Maximum pressure generated by the pump

PN

Maximum operating pressure

Liquid temperature intervals

Version

Gasket

Minimum

Maximum

Standard

EPDM

-20°C (-4°F)

140°C (284°F)

Optional

FPM (FKM)

-10°C (14°F)

90°C (194°F)

For special requirements, contact the Sales and Service Department.

Maximum number of starts per hour

kW

0.25 -

3.00

4.00 -

7.50

11 - 22

30 - 37

45 - 75 90 – 160

Starts

per hour

60

40

25

16

8

4

Noise level
See the measuring surface sound pressure levels L

pA

in

Table 11

.

en - Translation of the original instructions

14

e-nscs Installation, Operation, and Maintenance Manual

Advertising