Xylem EPR IM Electric heater-circulator unit EPR (obsolete) User Manual

Page 17

Advertising
background image

17

Instruction manual Laing Electric heater circulator unit

www.lainginc.com

The desired room temperature must be set at the room thermostat. Simi-

larly, the room thermostat with timer should also be properly set. It should be

understood that the room thermostat with timer allows only one lower room

temperature level, which then will be activated by the timer. There will be no

corresponding decrease in the feed line temperature.

Instructions for the operation of the room thermostat with timer should be

taken from the manual provided with the unit.

The desired constant temperature for the feed line water, with which the

heating system will be heated until the room temperature has been reached,

must be set at the setting knob K.

The heating surfaces then will be heated with the preset constant tem-

perature until the preset room temperature has been reached. The heating

elements will then be turned off.

It is important that the set constant temperature is always lower than the

maximum permissible feed temperature. This is especially important for floor

heating applications.

Electrical Diagram RT

Electrical Diagram RTU